Meets NEMA GPO3, UPGM203, NFF16-101(Rolling Stock)
Recognised as a top performer in the electrical industry. Retains electrical properties without adverse effects to product strength and stability at elevated temperatures. Typical applications include general purpose electrical insulation, transformer spacers and supports, transportation components, high voltage appliance insulators, bus bar supports and switchgear.
Meets NEMA GPO3
A high performance electrical insulating material. Exceeds NEMA in dielectric strength, arc resistance and tracking resistance. Highly flame retardant and low smoke generating. Applications include high voltage appliance insulators, bus bar supports and barriers in switchgear.
Meets NEMA LI-1 GPO3, UPGM 203, DIN 7735 HM2471
Excellent electrical insulation properties. Tracking resistance up to CTI 600. The most modern SMC press system allows for a sheet thickness of 130mm with a tolerance of ±0.1mm. A sheet length of up to 3720mm. Typical applications include the transformer, rail, switchgear and high-voltage industries
This data, while believed to be accurate and based on reliable analytical methods, is for informational purposes only. Data supplied above are "Typical Values", not to be considered "Specification Values".
Product | Test | H900 | HST2 | THIOLYTE 575 | Unit |
---|
STANDARD | NEMA L1 | DPO3 | |||
EN60893 | UPGM203 | UPGM205 |
Mechanical | |||||
TENSILE STRENGTH | ISO 527 | 76 | 89 | 160 | MPa |
FLEXURAL STRENGTH | ISO 178 | 152 | 172 | 350 | MPa |
MODULUS OF ELASTICITY | ISO 178 | 10300 | 12248 | 20000 | MPa |
COMPRESSIVE STRENGTH | ISO 604 | 207 | 227 | 500 | MPa |
IMPACT STRENGTH - IZOD | ISO 180 | 4.3 | 5.4 | J/cm | |
SHEAR STRENGTH | ASTM D-732 | 94 | 107 | MPa | |
BOND STRENGTH | ASTM D-229 | 6228 | 6228 | N | |
BARCOL HARDNESS | ASTM D-2583 | 62 | 62 | ||
SPECIFIC GRAVITY | ISO 1183 | 1.85 | 1.62 | 1.9 | |
WATER ABSORPTION | ISO 62 | 0.2 | 0.3 | 0.1 | % |
ELECTRICAL | |||||
TRACK RESISTANCE | IEC60587 | 1000 | Min | ||
ARC RESISTANCE | D-495 | 190 | 150 | Seconds | |
COMPARATIVE TRACKING INDEX | IEC60112 | 600+ | 600 | ||
DIELECTRIC STRENGTH, PERP. | IEC60243-1 | 22 | 15.8 | 13 | kV/mm |
DIELECTRIC STRENGTH, PARALLEL | IEC60243-1 | 55 | 62 | 60 | kV |
DIELECTRIC CONSTANT @ 60 Hz | IEC60250 | 5.2 | 4.2 | ||
DISSIPATION FACTOR @60 Hz | IEC60250 | 0.06 | 0.01 | ||
UL FLAME RESISTANCE | UL94 | V-O | V-O | ||
FLAME RESISTANCE | ASTM D-229 | ||||
IGNITION TIME | METHOD 2 | 120 | 77 | Seconds | |
BURNING TIME | 65 | 256 | Seconds | ||
RADIANT PANEL | ASTM E-162 | 5 | |||
SMOKE DENSITY @ 4Min. FLAME | ASTM E-662 | 0.33 | |||
FLAME SPREAD INDEX | UL E-84 | < 25 | |||
SMOKE DEVELOPED INDEX | UL E-84 | 340 | |||
UL THERMAL INDEX, ELEC/MECH | UL 746 B | 160/150 | 220/210 | 155 | °C |
COEFFICIENT OF THERMAL EXP. | ASTM D696 | 27 x 10-6 | 29 x 10-6 | 20 x 10-6 | u/u/°C |
NF16-101 ROLLING STOCK | NF P92-501 | M1 | |||
FIRE BEHAVIOUR | STM S-001 | F0 |